Product characteristics | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Measuring range |
|
||||||||||
Process connection | threaded connection G 1/4 internal thread | ||||||||||
Application | |||||||||||
Special feature | Gold-plated contacts | ||||||||||
Application | for industrial applications | ||||||||||
Media | liquids and gases | ||||||||||
Medium temperature [°C] | -25…80 | ||||||||||
Min. bursting pressure |
|
||||||||||
Pressure rating |
|
||||||||||
Type of pressure | relative pressure | ||||||||||
Electrical data | |||||||||||
Operating voltage [V] | 18…32 DC; (to SELV/PELV) | ||||||||||
Current consumption [mA] | < 35 | ||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Power-on delay time [s] | 0.3 | ||||||||||
Integrated watchdog | yes | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||||
Electrical design | PNP/NPN | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||
Switching frequency DC [Hz] | < 500 | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4…20; (scalable 1:4) | ||||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | ||||||||||
Analogue voltage output [V] | 0…10; (scalable 1:4) | ||||||||||
Min. load resistance [Ω] | 2000 | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Measuring/setting range | |||||||||||
Measuring range |
|
||||||||||
Set point SP |
|
||||||||||
Reset point rP |
|
||||||||||
Analogue start point |
|
||||||||||
Analogue end point |
|
||||||||||
In steps of |
|
||||||||||
Factory setting |
|
||||||||||
Accuracy / deviations | |||||||||||
Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) | ||||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||||
Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) | ||||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (0…80 °C) | ||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0…80 °C) | ||||||||||
Response times | |||||||||||
Response time [ms] | < 1.5 | ||||||||||
Damping process value dAP [s] | 0.01…4 | ||||||||||
Damping for the analogue output dAA [s] | 0.01…4 | ||||||||||
Max. response time analogue output [ms] | 3 | ||||||||||
Software / programming | |||||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span | ||||||||||
Interfaces | |||||||||||
Communication interface | IO-Link | ||||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.0 | ||||||||||
Profiles | no profile | ||||||||||
SIO mode | yes | ||||||||||
Required master port type | A | ||||||||||
Process data analogue | 1 | ||||||||||
Process data binary | 2 | ||||||||||
Min. process cycle time [ms] | 2.3 | ||||||||||
Supported DeviceIDs |
|
||||||||||
Operating conditions | |||||||||||
Ambient temperature [°C] | -25…80 | ||||||||||
Storage temperature [°C] | -40…100 | ||||||||||
Protection | IP 65 | ||||||||||
Tests / approvals | |||||||||||
EMC |
|
||||||||||
Shock resistance |
|
||||||||||
Vibration resistance |
|
||||||||||
MTTF [years] | 131 | ||||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||||
Mechanical data | |||||||||||
Weight [g] | 261.5 | ||||||||||
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | ||||||||||
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM | ||||||||||
Min. pressure cycles | 100 million | ||||||||||
Process connection | threaded connection G 1/4 internal thread | ||||||||||
Restrictor element integrated | no (can be retrofitted) | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Display unit | mbar; kPa; psi; inH2O | ||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
سنور فشار PN2027
- Two switching outputs, one of them programmable as analogue output
- Clearly visible 4-digit LED display
- Country-specific pressure units selectable
- With long-term stability thanks to high overload protection
- Selectable output polarity
از شما مشتریان عزیز خواهشمندیم به دلیل نوسانات بازار قبل از خرید تماس بگیرید.
Category: سنسور فشار
Description
Reviews (0)
Be the first to review “سنور فشار PN2027” لغو پاسخ
Reviews
There are no reviews yet.